Covered electrode for Welding Unalloyed and
Low-alloy Steels
|
Rutile-Cellulosic Covering |
|
|
|
Standards : |
EN 499 |
E 38 0 RC 11 |
|
DIN 1913 |
E 43 22 R(C) 3 |
|
AWS/ASME SFA-5.1 |
E6013 |
|
TS 563 |
E 43 22 R(C) 3 |
|
|
Application and Properties
: |
General-purpose electrode for structural
steelwork, workshop and maintenance welding. Easily operated in
positional welding, including vertically-down. Good gap-bridging.
Possible to use equally well both with AC and DC. Smooth arc, well
suited for tack-welding due to it's easy arc striking and restriking
properties. Welds are smooth, slightly concave and blending into
base metal without undercutting. Slag is self-releasing in most
cases. Suitable for welding on galvanized, primer painted and sligthly
rusted components.
|
|
Materials : |
S185 - S355 |
St 33 - St 52-3 |
P235GH, P265GH |
H I, H II |
P295GH |
17 Mn 4 |
P235 - P355 |
St 37.4 - St 52.4 |
P235, P265 |
St 35.8 - St 45.8 |
L210 - L360 |
StE210.7(TM) - StE360.7(TM) |
S(P)275 - S(P)355 |
StE 285 - StE 355 |
- |
StE 255 |
- |
GS-38, GS-52 |
GP240R |
GS-45 |
- |
A, B |
|
Please observe admissible operating
temperatures for welding consumable and base metal |
|
Qualification Tests |
: TSE |
|
|
|
|
All-Weld Metal Analysis
(typical values in %) : |
|
|
Mechanical Properties
of All-Weld Metal (single values are typical values): |
|
AW : As welded |
|
Redrying: Generally not required.
If required,redry 1hr. at 100-110°C |
|
Welding Current [A]:
|
40-60 |
55-85 |
90-140 |
130-180 |
180-230 |
|
|
Packing & Order
Information : |
1013004 |
2.00 |
300 |
300 |
3.00 |
4 |
12.00 |
1013010 |
2.50 |
350 |
115 |
2.07 |
6 |
12.42 |
1013016 |
3.25 |
350 |
115 |
3.43 |
4 |
13.71 |
1013020 |
4.00 |
350 |
100 |
4.59 |
4 |
18.36 |
1013028 |
5.00 |
350 |
70 |
4.79 |
4 |
19.15 |
|
|
Type of Current/Polarity/Welding
Positions : |
You can click on the figure to
see its explanation... |
|
|